welcome to official website

Products

Products

MITSUBISHI PLC-Q06UDVCPU


Part number/model Number: Q06UDVCPU 

New and Original

In stock and fast delivery with Fedex or DHL

Warranty: 12 months. / one year 



Contact

  1. Email:

    info@gisonauto.com

    Tel:
    +86 132 261 29957


  • Ins
  • LinkedIn
  • Facebook
  • WhatsApp
  • WA Business

Product details

MITSUBISHI PLC-Q06UDVCPU 


Brand : Mitsubishi Electric


Product No. : Q06UDVCPU


Universal model high speed type QCPU: Q06UDVCPU

 

control method : Stored program iteration operation

 

Input / output control method : Refresh method

(Direct access input / output possible by specifying direct access input / output (DX, DY))

 

Programming language :- Sequence control language : Relay symbol word, logic symbolic word, MELSAP 3 (SFC), MELSAP-L, function block, structured text (ST)

 

Peripheral connection port : USB, Ethernet

 

Memory card interface : Yes (SD memory card)

 

processing speed :- Sequence instructions LD X 0 : 1.9 ns

 

MOV D 0 D 1 : 3.9 ns

 

Constant scan : 0.5 ~ 2000 ms (Can be set in 0.1 ms increments)

 

Program capacity : 60K steps (240K bytes)

 

Memory capacity :- Program memory (drive 0) : 240 KB

 

Memory card (SD) (Drive 2) : Installed SD memory card (SD / SDHC) capacity (up to 32 GB)

 

Standard RAM (Drive 3) When the extended SRAM cassette is not used : 768 KB

 

When using extended SRAM cassette : Capacity when the extended SRAM cassette is not used + capacity of the

extended SRAM cassette (Extended SRAM cassette can be up to 8 Mbytes)

 

Standard ROM (Drive 4) : 1025.5 KB

 

CPU shared memory QCPU standard area : 8 KB

 

High speed communication area between multiple CPUs : 32 KB

 

Maximum number of stored files :- Program memory : 124

 

Memory card (SD) SD : Root folder: Up to 512

subdirectories: Maximum 65534

 

SDHC : Root folder: Maximum 65535 books

Subdirectory: Up to 65534 books

 

Standard RAM : 323 books

 

Standard ROM : 256

 

Intelligent functional unit Parameter Maximum setting number :- Initial setting : 4096 pieces

 

refresh : 2048 pieces

 

Number of program memory writes : Up to 100,000 times

 

Number of standard ROM writes : Up to 100,000 times

 

Number of input / output devices : 8192 points (X / Y 0 to 1 FFF)

 

Number of input / output points : 4096 points (X / Y 0 to FFF)

 

Number of device points :- Internal relay [M] : Default 15360 points (M0 to 15359) (changeable)

 

Latch relay [L] : Default 8192 points (L0 to 8191) (changeable)

 

Link relay [B] : Default 8192 points (B 0 to 1 FFF) (changeable)

 

Timer [T] : Default 2048 points (T0 ~ 2047) (shared low-speed timer / high speed timer) (changed)

the low-speed timer / high speed timer is specified by the instruction

unit of measurement of the low-speed timer / high speed timer is set in the parameter

(low-speed timer: 1 ~ 1000ms , 1 ms

increment, default 100 ms)(High-speed timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms)

 

Integration timer [ST] : Default 0 point (Shared for low speed integration timer / high speed integration timer) (changeable)

Low speed integration timer / high speed integration timer is set by

instruction Set the measurement unit of low speed integration timer / high speed integration timer by parameter

(low speed integration timer: 1 ~ 1000 ms, 1 ms

increment, default 100 ms)(High-speed integration timer: 0.01 to 100 ms, 0.01 ms increments, default 10.0 ms)

 

Counter [C] : Normal counter: default 1024 points (C 0 ~ 1023) (changeable)

 

Data register [D] : Default 22528 points (D0 to 22527) (changeable)

 

Extended data register [D] : Default 0 point (changeable)

 

Link register [W] : Default 8192 points (W 0 to 1 FFF) (changeable)

 

Extended link register [W] : Default 0 point (changeable)

 

Annunciator [F] : Default 2048 points (F0 to 2047) (changeable)

 

Edge relay [V] : Default 2048 points (V 0 to 2047) (Changeable)

 

: File register [R] When the extended SRAM cassette is not used : 32768 points (R 0 to 32767)

Up to 393216 points can be used by block switching

 

When using Q4 MCA - 1 MBS : 32768 points (R 0 ~ 32767)

Up to 917504 points can be used by block switching

 

When using Q4 MCA - 2 MBS : 32768 points (R 0 ~ 32767)

Up to 144,1792 points can be used by block changeover

 

When using Q4 MCA - 4 MBS : 32768 points (R 0 to 32767)

Up to 2490368 points can be used by block switching

 

When using Q4 MCA - 8 MBS : 32768 points (R 0 to 32767)

Maximum 4587520 points can be used by block switching

 

: File register [ZR] When the extended SRAM cassette is not used : 393216 points (ZR 0 to 393215)

Blockswitchingnot required

 

When using Q4 MCA - 1 MBS : 917504 points (ZR 0 to 917503) No

blockswitchingrequired

 

When using Q4 MCA - 2 MBS : 1441792 points (ZR 0 to 1441791)

Blockswitchingnot required

 

When using Q4 MCA - 4 MBS : 2490368 points (ZR 0 to 2490367)

Blockswitchingnot required

 

When using Q4 MCA - 8 MBS : 4587520 points (ZR 0 to 4587519)

Blockswitchingnot required

 

Link special relay [SB] : Default 2048 points (SB 0 to 7 FF) (changeable)

 

Link special register [SW] : Default 2048 points (SW 0 to 7 FF) (changeable)

 

Step relay [S] : Default 8192 points (S0 to 8191) (changeable)

 

Index register / general operation register [Z] : Up to 20 points (Z 0 ~ 19)

 

Index register [Z] (when 32-bit qualification of ZR device is specified) : Up to 10 points (Z0 to 18) (Use index register [Z] as double word)

 

Pointer [P] : 4096 points (P 0 ~ 4095) (Device number is fixed) Usable

range of local pointer / common pointer can be set by parameter

 

Interrupt pointer [I] : 256 points (I 0 to 255) (the number of device points is fixed)

Periodic interval of system interrupt pointer I 28 to 31 can be set by parameter (0.5 to 1000.0 ms, 0.5 ms increments)

Default I 28: 100 ms, I 29: 40 ms, I 30: 20 ms , I31: 10 ms

 

Special relay [SM] : 2048 points (SM 0 to 2047) (the number of device points is fixed)

 

Special register [SD] : 2048 points (SD 0 to 2047) (the number of device points is fixed)

 

Function input [FX] : 16 points (FX 0 to F) (the number of device points is fixed)

 

Function output [FY] : 16 points (FY 0 to F) (the number of device points is fixed)

 

Function register [FD] : 5 points (FD 0 ~ 4) (Device number is fixed)

 

Latch (power outage hold) range : L 0 to 8191 (default 8192 points)

[latch range can be set for B, F, V, T, ST, C, D, W]

 

RUN / PAUSE contact : One point of each RUN / PAUSE contact can be set from X 0 to 1 FFF

 

Clock function : Year, month, day, hour, minute, second, day of the week (Automatic leap year discrimination)

accuracy: -2.97 ~ + 3.75s (. TYP + 0.39s) / d at 0 ?

accuracy: -2.97 ~ + 3.75s (TYP + .0.39 s) / d at 25 ° C

Accuracy: -12.77 to + 2.13 s (TYP. -5.32 s) / d at 55 ° C

 

Allowable momentary power failure time : Depends on power supply unit

 

DC 5 V Internal current consumption : 0.58 A (single CPU unit) / 0.6 A (when extended SRAM cassette is installed)

 

External dimensions :- Height (H) : 98 mm

 

Width (W) : 27.4 mm

 

Depth (D) : 115 mm

 

mass : 0.20 kg

 

Built-in Ethernet function section :

 

Transmission specification :- Data transmission speed : 100/10 Mbps

 

Communication mode : Full duplex / half duplex

 

Transmission method : Baseband

 

Hub and node longest distance : 100 m

 

Maximum number of nodes / connection 10 BASE-T : Up to 4 cascade connections

 

100 BASE-TX : Maximum 2 cascade connections

 

Number of connections : Socket communication, MELSOFT connection, MC protocol total 16 pieces

1 for FTP

 

CC-Link IE Field Network Basic Performance Specification :

 

1 Number of network connections :- Master station : One

 

Slave station : 16 units

 

Number of occupied stations of slave stations : 1 to 4 stations

 

Maximum number of links per network :- RX : 1024 points

 

RY : 1024 points

 

RWr : 512 points

 

RWw : 512 points

 

Maximum number of links per station :- : Master station RX : 1024 points

 

RY : 1024 points

 

RWr : 512 points

 

RWw : 512 points

 

: Slave station RX : 64 points (occupies 1 station)

128 points (occupies 2 stations)

192 points (occupies 3 stations)

256 points (occupies 4 stations)

 

RY : 64 points (occupies 1 station)

128 points (occupies 2 stations)

192 points (occupies 3 stations)

256 points (occupies 4 stations)

 

RWr : 32 points (occupies 1 station)

64 points (occupies 2 stations)

96 points (occupies 3 stations)

128 points (occupies 4 stations)

 

RWw : 32 points (occupies 1 station)

64 points (occupies 2 stations)

96 points (occupies 3 stations)

128 points (occupies 4 stations)

 

UDP port number used for cyclic transmission : 61450

 

Transmission specification :- Data transmission speed : 100 Mbps

 

Number of cascade connection stages 100 BASE-TX : Check the manufacturer of the switching hub to be used for the number of connectable stages when using the switching hub.

 

Transmission path format : Star type

 

communication cable : Ethernet cable that meets 100BASE-TX standard

 

Maximum inter-station distance : Up to 100 m (conforming to ANSI / TIA / EIA - 568 - B (Category 5 e))

 

Total extension distance : Depends on system configuration

 

Shipping Weight : 2 Kg


Related Products


Trade Terms:  EXW Guangzhou, China

 

Payment Methods:  

 

Accepted Payment Currency: USD, CNY

 

Accepted Payment TypeTT Bank transfer , Western Union , Paypal etc.

 

Shipping Ways:   

 

DHL/FedEx/UPS/TNT/EMS/Aramex for fast and Door-to-Door shipment.

 

By Air or by Sea for bulk of batch goods.

 

Customer can specify freight forwarders or other shipping Methods.

Welcome to contact us for more details

 

Phone(Whatsapp):

 

+86 13600029957 (Alicia)

 

+86 19902276499 (Zolynn )






  • Prev: Q13UDVCPU | Mitsubishi Electric
    Next: Q64P | Power Supply Module
    Back to list